29
4. Additional Information
Specifications
Detector
Type Amorphous-Silicon Microbolometer
Spectral Response 7 to 14 microns
Thermal Performance
Time to Operation ~ 5 seconds
Contrast/Level Automatic (Electronic Image Control)
Image Touch-up Automatic (mechanical shutter)
Color Modes
White/Black Hot, HTL I, HTL II, and
Custom Color
Range to Detect Human
Activity
735 meters
Optics
Field of View 12° × 9°
Focal Length 25 mm
Focus Range 4 feet to infinity
Video
Viewfinder Display Color LCD
Viewfinder Brightness Adjustable (integral to on/off switch)
Auxiliary Video Out Output jack on rear (NTSC format)
Power
Power 2 AA Lithium Batteries
Operating Time
2 hrs continuous operation (alkaline
batteries*); 6 hrs (lithium batteries)
Auxiliary Power In 12Vdc (input jack on rear)
* The X320 can run on AA Alkaline batteries but performance and battery life may be
inconsistent.
Comentarios a estos manuales